Brand Name: SIEMENS
Model Number: 3RT
Place of Origin: CHINY
Orzecznictwo: CE,CCC etc.
Minimum Order Quantity: 1 jednostka
Price: USD12~USD198(~3P/185A)
Supply Ability: 1000 sztuk / miesiąc
Delivery Time: 5-8 dni roboczych lub zamówienie zbiorcze do negocjacji
Payment Terms: T/T, Western Union
Standard Packaging: Standardowe funkcje eksportu karton

Product Details


Prąd znamionowy obwodu głównego: 7–185 A. Rodzaj prądu: AC, AC / DC
Napięcie znamionowe obwodu głównego: 600 V, 220 V, 380 V, 110 V, 24 V. Liczba biegunów: 3,4
Fazy: 3,1 fazy Częstotliwość: 50 / 60Hz
Nazwa produktu: Stycznik Ac CJX2N-D09,3 biegun Stycznik Ac Prąd znamionowy: 185A
standardowe: IEC60947, EN / IEC60947-4-1
Podkreślić

stycznik domowy ac

,

centralny stycznik ac

Product Description

SIEMENS 3RT6016, IECContactor 7A, 9A, 12A, 25A, 32A, 40A, 50A, 63A, 80A do 185A, AC-3 AC-1 Napięcie cewki 24 V, 110 V, 230 V, 380 V

Charakterystyka
• Zakres prądu 07 ~ 185A;
• Cewka sterująca AC, DC jest opcjonalna;
• Dostępne są różne typy rozruszników: standardowe styczniki rozruchu silnika, styczniki odwracalne, rozruszniki gwiazda-trójkąt, rozruszniki autotransformatorowe itp.
• Certyfikacja produktu: CCC, CE, CCS;


Korzyść
• Kompaktowa instalacja
> Instalacja tłumika przepięć nie wymaga narzędzi i może być włożona bezpośrednio do stycznika bez zajmowania więcej miejsca
> Stycznik dwustronny ma tylko 90 mm szerokości, mechaniczne blokowanie nie zajmuje dodatkowej przestrzeni, instalacja nie zajmuje prawie czasu
> Komponenty rozruchowe zapewniają wstępnie okablowane moduły do ​​szybkiego i łatwego montażu
• Wysoce zintegrowany
> do 100A integracja stycznika 1 normalnie otwarty / 1 normalnie zamknięty styk pomocniczy
> Cewka DC z wbudowaną dwukierunkową diodą tłumiącą
> Odwracalna grupa styczników z wbudowaną dwukierunkową diodą tłumiącą
• Bezpieczny i niezawodny
> Obwód główny i obwód sterowania elementów sterowania i zabezpieczeń są wyraźnie rozróżnione
> Lustrzana konstrukcja styków, która spełnia standardy bezpieczeństwa, zapewniając 10 milionów niezawodnych działań
> Pokrywa ochronna zapobiega przypadkowemu kontaktowi ze stycznikiem
• wyjątkowa jakość
> Cewki DC mają szeroki zakres napięć sterujących (0,7 ~ 1,25Uc)
> Silna odporność na trzęsienia ziemi
> niższy hałas
> Zwiększona wytrzymałość terminala

> Stały moment obrotowy, niezawodny montaż
> Kompaktowy i oszczędzający miejsce
> Łatwy w instalacji, oszczędza czas

> Łatwość konserwacji i oszczędność kosztów

main information

Product Series

3RT

product name

AC Contactor

product type

Contactor

Product short name

3RT

Contactor application area

Applied to AC loads with a power factor greater than or equal to 0.95
Squirrel cage motor for switching on and off normal start

Use category

AC-3
AC-1
AC-4

Number of poles

3P

Power pole contact composition

3 NO

Rated working voltage [Ue]

Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC

Rated operating current [Ie]

18 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit
32 A 60 °C) on <= 440 V AC AC-1 for power supply circuit

Motor power (kW)

4 kW on 220...230 V AC 50/60 Hz (AC-3)
7.5 kW on 380...400 V AC 50/60 Hz (AC-3)
9 kW on 415...440 V AC 50/60 Hz (AC-3)
10 kW on 500 V AC 50/60 Hz (AC-3)
10 kW on 660...690 V AC 50/60 Hz (AC-3)
4 kW on 400 V AC 50/60 Hz (AC-4)

Motor power HP (UL / CSA)

1 hp on 115 V AC 50/60 Hz for 1-phase motors
3 hp on 230/240 V AC 50/60 Hz for 1-phase motors
5 hp on 200/208 V AC 50/60 Hz for 3-phase motors
5 hp on... 230/240 V AC 50/60 Hz for 3-phase motors
10 hp on 460/480 V AC 50/60 Hz for 3-phase motors
15 hp on 575/600 V AC 50/60 Hz for 3-phase motors

Control loop characteristics

AC on 50/60 Hz

Control loop voltage

230 V AC 50/60 Hz

Auxiliary contact type

1 NO + 1 NC

Rated impulse withstand voltage [Uimp]

6 kV in accordance with IEC 60947

Overvoltage category

III

Conventional heating current [Ith]

10 A on <60 °C for signal circuit
32 A on <60 °C for power supply circuit

Rated turn-on capability [Irms]

140 A AC suitable signal circuit in accordance with IEC 60947-5-1
250 A DC suitable signal loop in accordance with IEC 60947-5-1
300 A on 440 V applicable power supply circuit in accordance with IEC 60947

Rated breaking capacity

300 A on 440 V applicable power supply circuit in accordance with IEC 60947

Rated short-time withstand current [Icw]

145 A on <40 °C - 10 s for power supply circuit
240 A on <40 °C - 1 s for power supply circuit
40 A on <40 °C - 10 minutes for power circuit
84 A on <40 °C - 1 minute for power circuit
100 A - 1 s for signal circuits
120 A - 500 ms Applicable signal loop
140 A - 100 ms for signal circuits

Fuses used with relays

10 A gG Applicable signal circuit in accordance with IEC 60947-5-1
50 A gG on...<= 690 V with type 1 for power supply circuit
35 A gG on ...<= 690 V with type 2 for power supply circuit

Average impedance

2.5 mΩ - Ith 32 A 50 Hz for power supply circuits

Rated insulation voltage [Ui]

Power circuit: 690 V in accordance with IEC 60947-4-1
Power circuit: 600 V CSA certification
Power circuit: 600 V UL certification
Signal loop: 690 V in accordance with IEC 60947-1
Signal loop: 600 V CSA certified
Signal circuit: 600 V UL certification

Electrical life

1.65 kA2.s 18 A AC-3 Ue condition <= 440 V
1 kA2.s 32 A AC-1 Ue condition <= 440 V

Power consumption per pole

2.5 W AC-1
0.8 W AC-3

Safety cover

band

Installation method

Rail mounting
Base plate installation

standard

CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

Product Highlights

SIEMENS 3RT6016, IECContactor 7A, 9A, 12A, 25A, 32A, 40A, 50A, 63A, 80A do 185A, AC-3 AC-1 Napięcie cewki 24 V, 110 V, 230 V, 380 V Charakterystyka • Zakres prądu 07 ~ 185A; • Cewka sterująca AC, DC jest opcjonalna; • Dostępne są różne typy rozruszników: standardowe styczniki rozruchu silnika, ...

Related Products
Jakość Gotowy do zainstalowania Skrzynka rozdzielcza typu MCB RCCB RCBO Dla domu AC220 ~ 240V Przychodzące 63A fabryka

Gotowy do zainstalowania Skrzynka rozdzielcza typu MCB RCCB RCBO Dla domu AC220 ~ 240V Przychodzące 63A

Ready to Install Type A Distribution Box with MCB, RCCB or RCBO Custom for Home Use AC220~240V Incoming 63A Material: ABS/PC Color: Grey White/Transparent Cover Application: Power Distributing Type: Distribution Box Electrical Boxes Installation Type: Surface Type/ Flush Type Standard: IEC60439-3 ...

Jakość Wyłącznik elektryczny 6kA, 2-biegunowy wyłącznik 1 ~ 63A 1P 3P 4P 1P + N fabryka

Wyłącznik elektryczny 6kA, 2-biegunowy wyłącznik 1 ~ 63A 1P 3P 4P 1P + N

Osmart OSMC32N 6kA Schneider Electric Miniature Circuit Breaker 1~63A, 1P,2P,3P,4P,1P+N in compliance with IEC-EN60898 Osmart OSMC32N MCBs Schneider Electric Original Made In China Miniature Circuit Breakers up to 63 A characteristic * Product standard: GB10963.1/IEC 60898 * Product Certification: ...

Jakość Pojedyncza nadmuchiwana zmiana koloru światła LED RGB, oświetlenie imprezowe Balonowe lampki LED fabryka

Pojedyncza nadmuchiwana zmiana koloru światła LED RGB, oświetlenie imprezowe Balonowe lampki LED

Single RGB LED lighting Source Muse™130C Events Lighting Balloon with 72w/96w Color Changing LED 1. General features Smart Color LED changer balloon light Muse-Color Dual White, Muse-Color RGB+CCTpowered by LED bulb 72w, max 96w Print your company logo or event name on our giant advertising balloon ...

Jakość Ustawienia cyfrowe Modułowe przekaźniki czasowe AC DC 12V 24V fabryka

Ustawienia cyfrowe Modułowe przekaźniki czasowe AC DC 12V 24V

RT8-K Digital Setting Timer Relay AC DC 12V 24V 220V 230V Multifunction Time Delay on off Relay General Multifunctional time relay with digital settings can be used for industrial equipment, lighting control, heating element control, motor and fan control. It has four delay modes and the delay range ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.